Availability: | |
---|---|
Quantity: | |
6-GFM-100
OEM
12V 100AH Solar Gel Battery: Optimal Energy Storage for Sustainable Living. The AGM gel solar battery, conbined with AGM and high capacity lead plates, charged with gel glue to activated the plates to store power energy, and whenever you need, the power will be used through inverters or UPS systems to provide power to the electronics applications, offering a reliable and efficient way to store renewable energy for off-grid living and more.
Product Advantage
1. Easy Maintenance: The sealed and maintenance-free design saves time and effort, ensuring a low-hassle experience
2. Safety- with the valves covering on the acid filling wholes, when the internal pressure is getting higher, the valves will open and release the pressure power and there will be no danger with harm gas or electrolyte.
3. Low self-discharge rate: high quality Pb Ca alloy plates are used, the over potential of hydrogen precipitation is increased, and the self-discharge rate of the battery is reduced
4. Long Lifespan: Benefit from a durable battery with a long service life, reducing the need for frequent replacements.
.
Technical Parameters
Standard Voltage: | 12V |
Battery Capacity | 100AH |
Floating Charging Voltage: | 2.275-2.3V/cell |
Discharging Rate: | 0.1-0.25C |
Max Discharging Currnt Rate: | 0.1C |
Terminal: | M8 Coppers |
Working Temperature: | -20℃ to 50℃(-4℉ to 122℉) |
Dimensions: | 329*172*216 mm |
Carton Size: | 350*186*265 mm |
Pieces/ Carton | 1 PCS |
Storage Self-loss: | 3%-4% per month at 25℃ (-4℉) |
Battery Unit Weight: | 27KGS |
Designed Life: | 10 Years |
Warranty: | 3Years |
Product Uses
Solar and Wind Energy Systems: In off-grid and renewable energy setups, these batteries are used to store energy generated during the day for use at night or during periods of low generation.
Uninterruptible Power Supply (UPS): Front terminal batteries are used in UPS systems to provide backup power to critical loads in case of a power outage.
Telecommunications: Used as backup power sources for base stations and other communication equipment to ensure continuous operation during power outages.
Emergency Lighting and Alarm Systems: In buildings, these batteries provide power to emergency lighting and alarm systems in case of a power failure.
Industrial Equipment: Used in various industrial applications to power equipment that requires a reliable and steady power source.
Home Energy Storage: For residential use, front terminal batteries can store energy from solar panels or the grid for use during peak demand or outages.
Product Operation Guide
Storage Conditions: Store in a cool, dry place away from direct sunlight to prolong battery life.
Charging Guidelines: Use a smart charger designed for AGM batteries to ensure optimal charging and extend battery health.
Regular Checks: Periodically check the battery for any signs of damage or corrosion on the terminals.
Regular inspection: Regularly check the battery, including voltage, connecting wires for looseness and corrosion pollution, and deal with it in time.
Charging precautions: When charging, make sure that the ambient temperature is suitable, use a suitable charger, and follow the correct charging method.
Prevent sun exposure: Prevent the battery from being exposed to the sun, and it should be cooled down before charging after exposure to avoid cracking or deformation of the battery.
Proper Ventilation: Ensure the area around the batteries is well-ventilated to dissipate heat and prevent the buildup of hydrogen gas.
Secure Mounting: Mount batteries on stable and level racks or trays to prevent movement and potential damage to the terminals.
Correct Cable Gauge: Use the appropriate cable gauge to minimize resistance and voltage drop.
Polarity: Clearly mark and connect the positive and negative terminals to avoid short circuits.
Tight Connections: Ensure all connections are tight and secure to prevent loose connections that could cause sparks or corrosion.
12V 100AH Solar Gel Battery: Optimal Energy Storage for Sustainable Living. The AGM gel solar battery, conbined with AGM and high capacity lead plates, charged with gel glue to activated the plates to store power energy, and whenever you need, the power will be used through inverters or UPS systems to provide power to the electronics applications, offering a reliable and efficient way to store renewable energy for off-grid living and more.
Product Advantage
1. Easy Maintenance: The sealed and maintenance-free design saves time and effort, ensuring a low-hassle experience
2. Safety- with the valves covering on the acid filling wholes, when the internal pressure is getting higher, the valves will open and release the pressure power and there will be no danger with harm gas or electrolyte.
3. Low self-discharge rate: high quality Pb Ca alloy plates are used, the over potential of hydrogen precipitation is increased, and the self-discharge rate of the battery is reduced
4. Long Lifespan: Benefit from a durable battery with a long service life, reducing the need for frequent replacements.
.
Technical Parameters
Standard Voltage: | 12V |
Battery Capacity | 100AH |
Floating Charging Voltage: | 2.275-2.3V/cell |
Discharging Rate: | 0.1-0.25C |
Max Discharging Currnt Rate: | 0.1C |
Terminal: | M8 Coppers |
Working Temperature: | -20℃ to 50℃(-4℉ to 122℉) |
Dimensions: | 329*172*216 mm |
Carton Size: | 350*186*265 mm |
Pieces/ Carton | 1 PCS |
Storage Self-loss: | 3%-4% per month at 25℃ (-4℉) |
Battery Unit Weight: | 27KGS |
Designed Life: | 10 Years |
Warranty: | 3Years |
Product Uses
Solar and Wind Energy Systems: In off-grid and renewable energy setups, these batteries are used to store energy generated during the day for use at night or during periods of low generation.
Uninterruptible Power Supply (UPS): Front terminal batteries are used in UPS systems to provide backup power to critical loads in case of a power outage.
Telecommunications: Used as backup power sources for base stations and other communication equipment to ensure continuous operation during power outages.
Emergency Lighting and Alarm Systems: In buildings, these batteries provide power to emergency lighting and alarm systems in case of a power failure.
Industrial Equipment: Used in various industrial applications to power equipment that requires a reliable and steady power source.
Home Energy Storage: For residential use, front terminal batteries can store energy from solar panels or the grid for use during peak demand or outages.
Product Operation Guide
Storage Conditions: Store in a cool, dry place away from direct sunlight to prolong battery life.
Charging Guidelines: Use a smart charger designed for AGM batteries to ensure optimal charging and extend battery health.
Regular Checks: Periodically check the battery for any signs of damage or corrosion on the terminals.
Regular inspection: Regularly check the battery, including voltage, connecting wires for looseness and corrosion pollution, and deal with it in time.
Charging precautions: When charging, make sure that the ambient temperature is suitable, use a suitable charger, and follow the correct charging method.
Prevent sun exposure: Prevent the battery from being exposed to the sun, and it should be cooled down before charging after exposure to avoid cracking or deformation of the battery.
Proper Ventilation: Ensure the area around the batteries is well-ventilated to dissipate heat and prevent the buildup of hydrogen gas.
Secure Mounting: Mount batteries on stable and level racks or trays to prevent movement and potential damage to the terminals.
Correct Cable Gauge: Use the appropriate cable gauge to minimize resistance and voltage drop.
Polarity: Clearly mark and connect the positive and negative terminals to avoid short circuits.
Tight Connections: Ensure all connections are tight and secure to prevent loose connections that could cause sparks or corrosion.