Welcome To TG BATTERY
Lead acid battery 12V 150AH for UPS EPS and Solar System
Home » Products » Lead Acid Battery » 12V Lead Acid Battery » Lead acid battery 12V 150AH for UPS EPS and Solar System

Product Category

Leave Us Your Info

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
sharethis sharing button

Lead acid battery 12V 150AH for UPS EPS and Solar System

5 0 Reviews
Wholesale or retail sales are all accepted, if you have shipping agents in China, the EXW or FOB are ok, and if you don't have any, we could provide CIF or DDP,
There is no MOQ for regular Black, White and Grey batteries, and if special colors are requested, the MOQ would be 200pcs
MOQ for colorful carton boxes would be 200pcs, and US$1.5 will be surcharged for order between 100-200pcs 
Price: $ 96.5 / PCS
Availability:
Quantity:
  • 6-GFM-150

  • OEM

12V 150AH Lead acid battery, the electrode is mainly made of lead and its oxide, and the electrolyte is sulfuric acid solution. When been discharged, the main component of the positive electrode is lead dioxide, and the main component of the negative electrode is lead; When been charged, the main components of the positive and negative electrodes are lead sulfate, it is used for UPS, EPS, portable power station and some large medical equipments.



Technical Parameters

Standard Voltage:12V
Battery Capacity150AH
Floating Charging Voltage:2.275-2.3V/cell
Max Discharging Rate:0.1-0.25C
Max Charging Currnt:0.1C
Terminal:M8 Coppers
Working Temperature:-20℃ to 50℃(-4℉ to 122℉)
Dimensions:483*170*239 mm
Carton Size:496*183*273 mm
Pieces/ Carton1 PCS
Storage Self-loss:3%-4% per month at 25℃ (-4℉)
Battery Unit Weight:38KGS
Designed Life:10 Years
Warranty:3Years




Product Advantage


1. Sealed and Maintenance-Free: The sealed construction is safe for indoor use and requires minimal maintenance, offering a hassle-free experience.

2. Safety- with the valves covering on the acid filling wholes, when the internal pressure is getting higher, the valves will open and release the pressure power and there will be no danger with harm gas or electrolyte.

3. Low self-discharge rate: high quality Pb Ca alloy plates are used, the ovr potential of hydrogen precipitation is increased, and the self-discharge rate of the battery is reduced

4. Long Lifespan- at the temperature of 20 degrees, the design lifespan is 10 years and the floating life of the battery could be 3-5 years.

5.Low temperature resistance and high temperature resistance: Because the electrolyte is a lens structure, the lead crystal battery is less affected by the environment, and can work normally in a low temperature environment of minus 40 degrees, and is not affected by high temperature.

6.Non-dangerous goods certification: Lead-crystal battery has obtained a number of environmental protection quality certifications, and is the only product in the field of lead-acid battery that has obtained national non-dangerous goods certification, which can be transported as a conventional product.




Product Uses


  • Off-Grid Solar Systems: Ideal for off-grid homes and cabins, providing a reliable energy source independent of the main power grid.

  • Renewable Energy Storage: Efficiently stores energy generated by solar panels, ensuring a continuous supply of power even during periods of low sunlight.

  • Home Energy Storage: Perfect for home energy storage systems, supplementing grid power with stored solar energy for a more sustainable lifestyle.

  • Commercial Solar Farms: Supports commercial solar energy projects, ensuring a reliable and efficient energy storage solution.




Product Operate Guides


On the first charge, the battery should be charged until the remaining fifteen to thirty percent is used before charging, which helps the battery to circulate fully and avoid disrupting the charging cycle.


Do not charge for more than 8-10 hours for the first time to avoid the battery entering an over-float state, thereby reducing the battery life.


The first three charges of a brand new lead-acid battery are very important, and it is recommended to charge the battery in a timely manner when the battery has 10-25% remaining charge, and give enough charging time to keep it in the range of 6-10 hours.


When charging, connect the battery port first and then connect the power supply, and when charging is over, pull the power port first and then disconnect the battery.


Lead-acid battery charging should be carried out in a cool and ventilated location, avoiding high temperatures, closed or humid environments, which can cause damage to the battery.


Avoid charging at temperatures that are too high or too low, which will affect the performance and life of the battery.


For lead-acid batteries that are not used for a long time, it is recommended to charge them every 1-2 months, and cut off all lines connected to the battery in time to avoid the battery from depleting too quickly.


The battery is deeply discharged once every 1-2 months to activate the active material of the battery and prevent it from precipitating



Previous: 
Next: 
Guangdong Tiangang New Energy Technology Co., Ltd. is located in Kaiping City, Jiangmen City, Guangdong Province, China, the first overseas Chinese hometown in China.

Follow US

Quick Links

Product Category

Contact Us

 +86-750-2888908
  +86-17363235558
 +86-17363235558
 No 11, 1st Xiangyuan Road, Biaohai Industrial Zone, Shatang Town, Kaiping City, Jiangmen, Guangdong Province, China

Help

Leave a Message
Leave Us Your Info
​Copyright © 2024 Guangdong Tiangang New Energy Technology Co., Ltd. All rights reserved. | Sitemap | Supported by leadong.com